Recall365
RecallsUnited Kingdom › Unbranded Battery Charger QD-261078

Unbranded Battery Charger QD-261078 — recall

Consumer goods · United Kingdom · 2024-11-27
Hazard: Electric Shock

Unbranded Battery Charger QD-261078 was recalled in United Kingdom on 2024-11-27 due to electric shock. Non branded black charger described for DYSON V6 Vacuum Absolute Animal DC58,DC59,DC60,DC61,DC62,DC72

CountryUnited Kingdom
CategoryConsumer goods
Published2024-11-27
RetailereBay
Model identifiersModel: QD-261078; Barcode: 3954-DV-6-P; eBay Item number 394860508420
CategoryElectrical appliances and equipment
HazardElectric Shock
Hazard descriptionThe product presents a high risk of electric shock as it featured poor quality connections with wires soldered directly to the PCB. Additionally, the product only had one bridging capacitor whereas two or more in a series are required. Arcing could also be identified on the secondary side of the transformer. The plug face did not meet the dimensional requirements of the relevant standard as the live pin was too wide and short. Additionally, the neutral pin was too close to the edge of the plug, which allows access to live parts when plugging in, or unplugging, the plug from the socket.
Non-complianceElectrical Equipment (Safety) Regulations 2016 or the Plugs & Sockets (Safety) Regulations 1994
RemedyWe recommend owners stop using this product immediately. Contact the distributor you purchased from to request redress. The listing has been removed by the online marketplace (eBay).
Recall number2407-0169
Official noticeView source ↗

Stay ahead of recalls like this